www.apjph.comwww.apjph.com
...
Original research
Ref Number: APCP-OP-31

Are ADP-derived international fat mass references applicable to Sri Lankan newborn infants

Pathirage Don Madhya Kaumadi Chathurya Pathirage¹, Vasana Kiridana¹, Madhya Pathirage¹, Ridma Karunathilake¹, Gihani Vidanapathirana², Pujitha Wickramasinghe³, Chathura Rathnayake⁴, Sampath Tennakoon⁵, Nishan Kalupahana⁶
1- Department of Pediatrics, Faculty of Medicine, University of Peradeniya, Sri Lanka 2- Department of Medical Laboratory Science, University of Peradeniya, Sri Lanka 3- Department of Pediatrics, Faculty of Medicine, University of Colombo, Sri Lanka 4- Department of Obstetrics & Gynecology, Faculty of Medicine, University of Peradeniya, Sri Lanka 5- Department of Community Medicine, Faculty of Medicine, University of Peradeniya, Sri Lanka 6- Department of Nutrition and Health, College of Medical, United Arab Emirates
Corresponding Author: Pathirage Don Madhya Kaumadi Chathurya Pathirage (chathurya2525@gmail.com)
Abstract Body
Introduction: Higher adiposity in early life plays a pivotal role in the later development of obesity and non-communicable disease. Skin fold thickness (SFT) is a simple, cheap and non-invasive method of measuring adiposity . SFT-derived equations are commonly used in calculating fat mass. However, Air Displacement Plethysmography (ADP) remains the gold standard of fat mass estimation which is not readily available in clinical set-up. The alignment of SFT -derived fat mass with reference standards of ADP-derived fat mass remains uncertain. Objectives: To evaluate the alignment of estimated infant fat mass from SFT-derived equations relative to published ADPbased Lambda–Mu–Sigma (LMS) reference standards. Methods: In this prospective cohort study , suprailiac SFT of 203 infants were measured by the Harpenden Skinfold Caliper at birth. SFT-derived fat mass was estimated by the Catalano equation. Fat mass Z -scores were calculated using age and gender- specific LMS parameters of ADP based fat mass reference data. The Wilcoxon signed-rank test was performed to determine whether the median Z -score significantly differed from the reference median. Results: The median SFT-derived fat mass and the median Z score were 1.15 kg and 4.05, respectively . All the infants depicted a positive fat mass Z -scores relative to the ADP reference standards. The median Z -scores were significantly higher than the reference median (p < 0.05), indicating a systematic elevation in SFT-derived fat mass compared to ADP-based reference values. Conclusion: The systematic elevation in adiposity estimates of SFT derived infant fat mass highlights methodological or population-related differences when applying SFT-derived equations against ADP-based reference data.
Keywords: Neonatal fat mass; Air displacement plethysmography; Reference standards
Presentation Type: Original research
Disclaimer: The Views and opinions expressed in the articles are of the authors and not of the journal.
Editor-In-Chief
Journal Office
Mid City Hospital, 3-A Shadman II
Jail Road, Lahore ,Pakistan
Managing Editor
Dr. Intan Juliana Abd Hamid
Support & Help
Assistant Editor
Dr. Sadia Shabbir Hussain
Support & Help
Digital Content Editor
Dr. Khalid Masud
Administrator